NOTE-Never use
sandpaper or emery cloth to clean the contact points.
REVERSE POLARITY
If the polarity of the generator is reversed, the
circuit breaker contact points
will vibrate and burn. To
make sure the generator has the correct polarity after connecting it
with the regulator.
momentarily connect a jumper lead between the
generator (GEN) terminal and the
battery (BAT) terminal of
the regulator before starting the engine. The momentary surge of
battery current to the
generator will correctly polarize the generator.
|
RADIO BY-PASS CONDENSER
The installation of radio by-pass condensers of
too high capacity on the field
terminal of the regulator
or generator will cause the current and voltage
regulator contact points to oxidize. Oxidized
points cause a high resistance
and may result in a low
charging rate and a discharged battery. DO
NOT CONNECT RADIO BY-PASS
CONDENSERS TO THE FIELD
TERMINAL OF THE REGULATOR
OR GENERATOR other than as
furnished with the short wave
radio set, which is .01
mmfd. capacity.
If a condenser has been installed to the field
|
|
|
|
|
|
|
|
|
|
|
|